<?xml version="1.0" standalone="yes"?>
<?xml-stylesheet type="text/xsl" href="..\..\XSLTemplates\ErrorsStyleSheet.xsl"?>
<Error>
<ErrorNumber>7020</ErrorNumber>
<ErrorFamily>Carriage</ErrorFamily>
<ErrorMessage>
CARRIAGE: Carriage control board error: cable not detected or undervoltage
</ErrorMessage>
<AppliesTo>
<UnnumberedList>
<ListItem><Text>Trendsetter_400/800</Text></ListItem>
<ListItem><Text>Trendsetter_400/800_Proofing</Text></ListItem>
<ListItem><Text>Trendsetter_400/800_Auto</Text></ListItem>
<ListItem><Text>Trendsetter_NEWS</Text></ListItem>
</UnnumberedList>
</AppliesTo>
<ServiceInformation>
<DescriptionText><text>
The carriage driver has reported a fault.  Both control signals status0
and status1 are low (active).  Check the cables running to and from the
carriage driver board.  Also check the voltage levels on the board.
</text></DescriptionText>
<DescriptionText><text>
If the power cable is disconnected or logic power fault has occured, no status
LED's will be lit on the carriage drive board. If the control cable is
is disconnected, only the PWR status LED will be asserted. Ensure that the
safety loop is not active during trouble-shooting.
</text></DescriptionText>
<DescriptionText><text>
This error is only applicable if the new carriage driver is installed.  In that
case, the "sys hpd (high_pwr_drives)" will be set to 1.
</text></DescriptionText>
</ServiceInformation>
<OperatorAction>
<DescriptionText><text>
Click on CANCEL IMAGE. If the machine does not recover, turn the power
to the output machine off and on again.  Please contact Creo Service to report
this error.
</text></DescriptionText>
</OperatorAction>
<Cause>
Faulty/disconnected cable
</Cause>
<Cause>
Power supply failure
</Cause>
<SeeAlso>
<UnnumberedList>
<Link><LinkAddress>../nvs/sys_cfg_hpd.xml</LinkAddress><LinkTitle>NVS: sys hpd</LinkTitle></Link>
</UnnumberedList>
</SeeAlso>
<OtherLinks>
<Link><LinkAddress>..\..\ShowAllErrors.htm</LinkAddress><LinkTitle>Firmware 0 Error Index</LinkTitle></Link>
<Link><LinkAddress>..\..\ShowAllCommands.htm</LinkAddress><LinkTitle>Firmware 0 Command Index</LinkTitle></Link>
<Link><LinkAddress>..\..\ShowAllNVS.htm</LinkAddress><LinkTitle>Firmware 0 NVS Index</LinkTitle></Link>
</OtherLinks>
<Updated>
Updated: Wed Jul 16 19:32:29 2008 PST
</Updated>
<Links>
</Links>
</Error>